First, the goods and manufacturers information
Item Name: 3,4-Dichlorobenzotrifluoride |
Other names: 3,4-dichlorotrifluoromethylbenzene |
Suggestions for use and usage restrictions: / |
Manufacturer or supplier name, address and telephone number: /Zouping Qili Additives Co., Ltd. Houcheng Village, Daixi Office, Zouping County, Shandong Province, China |
Emergency contact number / fax number: 4780006/0543-4537355 |
Second, the danger mark
Item Name: 3,4-Dichlorobenzotrifluoride |
Hazard classification and national or regional information: The product is classified as: Hazardous to the aquatic environment - Long-term hazard category 2 |
GHS label elements, including precautionary statements: Signal word: No warning word Hazard statement: H411 is toxic to aquatic life with long-lasting effects. Precautionary statements: • Precautions: P273 Avoid release to the environment. • Incident Response: P391 collects spillage. • Safe storage: None • Disposal: P501 Dispose of contents/container in accordance with local regulations. Physical and chemical hazards: No data available Health hazards: No data Environmental hazards: Toxic to aquatic life with long lasting effects. |
Third, the component identification data
Pure substances:
Chemical name: 3,4-Dichlorobenzotrifluoride / |
Common name: / |
Chemical Abstracts Service Registration Number (CAS No.): 328-84-7 |
Hazardous substance composition (percentage of ingredients): / |
Mixture:
Chemical properties: / |
Hazardous substance composition: / |
Concentration or concentration range (percentage of ingredients): / |
Fourth, first aid measures
First aid methods for different exposure routes: / |
Inhalation: If inhaled, move the patient to fresh air. |
Skin contact: Remove contaminated clothing and wash skin thoroughly with soap and water. Get medical attention if you feel uncomfortable. |
Eye contact: Separate the eyelids and rinse with running water or saline. Seek medical attention immediately. |
Ingestion: Rinse mouth, no vomiting. Seek medical attention immediately. |
The most important symptoms and dangerous effects: / |
Protection that emergency personnel should take: / |
Indication of immediate medical attention and special treatment needed if necessary: / |
Fifith, Fire fighting measures
Extinguishing media: Extinguish with water spray, dry powder, foam or carbon dioxide. Avoid using DC water to extinguish the fire. Direct current water may cause splashing of flammable liquids and spread the fire. |
Hazardous characteristics: / |
Hazardous combustion products: / |
Special Fire Fighting Procedures: Firefighters should wear a gas-filled respirator, wear a full-body fire suit, and extinguish the fire in the upwind direction. Move the container from the fire to the open space as much as possible. If the container in the fire has changed color or sounded from a safe pressure relief device, it must be evacuated immediately. Isolation of the accident site, prohibiting unrelated personnel from entering.Contain and handle fire water to prevent environmental pollution. |
Sixth, leakage treatment method
Personal precautions, protective equipment and emergency procedures: It is recommended that emergency personnel wear inflatable breathing apparatus, antistatic clothing and rubber and oil resistant gloves. Do not touch or cross spills. All equipment used in the work should be grounded. Cut off the source of the leak as much as possible. Eliminate all ignition sources. The warning zone is delineated according to the influence area of liquid flow, steam or dust diffusion, and the unrelated personnel are evacuated from the crosswind and the upwind to the safe zone. |
Environmental precautions: Contain spills to avoid environmental pollution. Prevent spills from entering sewers, surface water and groundwater.Methods and materials for cleaning: Small spills: Collect leaking liquid as much as possible in a closable container. Absorb with sand, activated carbon or other inert materials and transfer to a safe place. It is forbidden to rush into the sewer. A large number of leaks: building a dike or digging a pit. Close the drain pipe. Cover with foam to inhibit evaporation. Transfer to a tank truck or special collector with an explosion-proof pump, recycle or transport to a waste disposal site for disposal. |
Seventh, Handling and storage
Handling Precautions: Operators should be specially trained to strictly follow the operating procedures. Handling should be carried out in a location with local or full ventilation. Avoid eye and skin contact and avoid inhaling steam. See Section 8 for personal protection measures. Keep away from fire, heat, and smoking in the workplace. Use explosion-proof ventilation systems and equipment. For canning, the flow rate should be controlled and grounded to prevent static buildup. Avoid contact with incompatible materials such as oxidizing agents (see Section 10 for incompatible materials). Lightly load and unload during handling to prevent damage to packaging and containers. Empty containers may be harmful residues. Wash hands after use and prohibit eating in the workplace. Equipped with the corresponding variety and quantity of fire-fighting equipment and leakage emergency treatment equipment. |
Storage Precautions: Store in a cool, ventilated warehouse. The temperature should not exceed 37 °C. It should be stored separately from oxidants and food chemicals, and should not be mixed (see Section 10 for incompatible materials). Keep the container sealed. Keep away from fire and heat. Lightning protection equipment must be installed in the warehouse. The exhaust system should be provided with a grounding device that removes static electricity. Explosion-proof lighting and ventilation settings. It is forbidden to use equipment and tools that are prone to sparks. The storage area should be equipped with leakage emergency treatment equipment and suitable containment materials. |
Eighth, contact control / personal protection
Engineering Control: Workplace recommendations are separate from other work sites. Closed operation to prevent leakage. Increase ventilation.Set up automatic alarms and accident ventilation. Set up emergency evacuation routes and necessary quarantine areas. Set the red area warning line, warning sign and Chinese warning instructions, and set the communication alarm system. Safety showers and eyewash equipment are provided. |
Respiratory protection: Wear a filter-type gas mask (half mask) when the concentration in the air exceeds the standard. Air-operated respirators should be worn during emergency rescue or evacuation. |
Eye protection: Wear chemical safety eye protection. |
Skin and body protection: Wear protective clothing to penetrate the overalls. |
Hand protection: Wear rubber and oil resistant gloves. |
Other protection: Smoking, eating and drinking are prohibited at the job site. After work, take a shower. Maintain good hygiene practices. |
Ninth, Physical and chemical properties
Appearance (physical status, color, etc.) | Colorless to pale yellow liquid |
odor | / |
Odour devaluation | / |
pH value | / |
Melting point / freezing point | −13-−12 °C (lit.) |
Boiling point (°C) | 173-174 °C (lit.) |
Flash point (°C) | 150 °F |
Evaporation rate | / |
Flammability (solid, gaseous) | / |
Upper and lower flammability limits or explosion limits | / |
Vapor pressure (kPa) | / |
Vapor density | / |
Relative density | / |
Solubility | / |
Uses | The intermediate used in the manufacture of pesticides is also a raw material for organic synthesis. |
Tenth, stability and reactivity
Chemical stability: This product is stable during storage and use at normal ambient temperature. |
Possibility of dangerous reactions: / |
Conditions to avoid (such as static unloading, shock or vibration): Electrostatic discharge, heat, humidity, etc. |
Incompatible materials and materials: oxides |
Dangerous decomposition products: / |
Eleventh, Toxic information
Route of exposure: inhalation, ingestion |
Symptoms about physical, chemical and toxicological characteristics: / |
Chronic toxicity or long-term toxic effects: / |
Quantitative measures of toxicity (eg acute toxicity estimates): LD50: 823 mg/kg (rat oral); LC50: no data available |
Twelveth, Ecological information
Ecotoxicity: / |
Persistence and degradability: / |
Bioaccumulation: / |
Mobility in the soil: / |
Other adverse effects: / |
Thirteen, Disposal methods :
Waste chemicals:
recycle as much as possible. If it cannot be recycled, it is disposed of by incineration. Do not dispose of this product by discharging it into the sewer.
Contaminated packaging:
return the container to the manufacturer or dispose of it in accordance with national and local regulations. Refer to national and local regulations before disposal.
Fourteen, Transportation information
Dangerous goods number: |
UN number: 1760 |
UN transport name: CORROSIVE LIQUID, NOS |
Transport hazard category: Category 8 |
Packing category: Class III |
Packing method: Pack according to the manufacturer's recommended method, for example: open steel drum. An ordinary wooden box outside the ampoule. Threaded glass bottles, iron caps, glass bottles, plastic bottles or metal barrels (cans) outside the ordinary wooden box. |
Transportation precautions: Transportation vehicles should be equipped with the appropriate variety and quantity of fire-fighting equipment and leakage emergency treatment equipment. It is strictly forbidden to mix and transport with oxidants and food chemicals. The vehicle exhaust pipe carrying the item must be equipped with a fire arresting device. When using a tank (tank) vehicle, there should be a grounding chain. A hole partition can be provided in the tank to reduce the static electricity generated by the shock. It is forbidden to use mechanical equipment and tools that are prone to sparks. It is best to transport in the summer and evening. During transportation, it should be protected from exposure, rain and high temperature. Keep away from fire, heat and high temperature areas during stopovers. When transporting by road, follow the prescribed route and do not stay in residential areas and densely populated areas. It is forbidden to slip when transporting by rail. It is strictly forbidden to transport in bulk by wooden or cement vessels. Hazard signs and notices shall be posted on the means of transport in accordance with the relevant transport requirements. |
Fifteen, Regulatory information
Applicable Regulations: The following laws, regulations, rules and standards provide for the management of the chemical: the Occupational Disease Prevention Law of the People's Republic of China: Classification of Occupational Disease Hazard Factors (2015): Not included in the Hazardous Chemicals Safety Management Regulations: Danger Catalogue of Chemicals (2015): List of Hazardous Chemicals Not Listed in Explosives (2017): List of Hazardous Chemicals Not Listed in Priority: First and Second Batch of List of Critically Controlled Hazardous Chemicals: Not Listed Environmental Management Registration Procedure for Hazardous Chemicals (Trial): List of Hazardous Chemicals for Key Environmental Management: Not included in the Regulations on the Administration of Narcotic Drugs and Psychotropic Substances: Catalogue of Narcotic Drugs: Not listed in the list of psychotropic substances: Not included in the new chemical environment Management Approach: List of Existing Chemical Substances in China (2013): |
Sixteen, Other information
references | / | |
Tabulation unit | Name: Zouping Qili Additives Co., Ltd. | |
Address / Tel: Houcheng Village, Daixi Office, Zouping County, Shandong Province, China /0543-4788006 | ||
Lister / | job title: | Name (signature): / |
Tabulation date / | / |
Note 1: When the product is a mixture containing two or more dangerous substances, a safety data sheet should be prepared according to the danger after mixing.
Note 2: The manufacturer/supplier should ensure the correctness of the information contained in the SDS according to the actual situation and update it as appropriate.
Note 3: The presence of certain characteristics without Due information (such as a solid having a boiling point not present), should form a "/" identifier.